N1289J Rockwell AC-112A accident

NTSB CHI85LA043 · 1984-11-02 · COLUMBUS, OH · near CMH

Docket — crew, injuries and powerplant

Factual narrative

THE ACFT EXPERIENCED A MAIN GEAR COLLAPSE DURING A LANDING ROLL. THE PLT CLAIMED THAT THE ACFT SUFFERED A FAILURE OF THEELECTRICAL SYSTEM SHORTLY AFTER INITIAL TAKEOFF. THE PLT LOWERED THE LNDG GEAR BUT WAS UNABLE TO ACHIEVE A GEAR DOWN & LOCKED INDICATION DUE TO THE ELECTRICAL FAILURE. THE RT MAIN GEAR COLLAPSED DURING LANDING. THIS WAS THE 1ST FLT SINCE AN ANNUAL INSPECTION DURING WHICH THE RT MAIN GEAR HYDRAULIC LINE WAS REPLACED. AFTER THE ACCIDENT, THE ACFT WAS JACKED UP ON THE RWY AND A BUNDLE OF SQUAT SWITCH WIRING FELL OUT OF THE WHEEL WELL. NO BUNDLE TIE WIRE WAS FOUND. AFTER THE ACFT WAS MOVED TO LANE AVIATION THE ENGINE WAS STARTED AND IT WAS DETERMINED THAT THE ALTERNATOR WAS NOT CHARGING. THE AMMETER INDICATED NO CHARGE OR DISCHARGE. WITH AN EXTERNAL JUMPER CABLE ATTACHED TO THE GEAR-UP RELAY A SUCCESSFUL GEAR RETRACTION WAS PERFORMED. AFTER THE BATTERY WAS CHARGED FROM AN EXTERNAL SOURCE, THE ALTERNATOR CAME ON LINE WITH 16.1 VOLTS BEFORE DROPPING OFF LINE AFTER APRX 2 MINS. THE ALTERNATOR PTS WERE PITTED & DIRTY. CLEANING DID NOT HELP.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
15
Wind direction
360
Wind speed (kt)
8
Temperature (F)
37
Nearest airport
COLUMBUS INTERNATIONAL
Distance from field
0.0
Airport elevation
816

Aircraft

RegistrationMakeModelDamageFAR part
N1289J Rockwell AC-112A SUBS 091

Sequence of events

#OccurrencePhase
1 130 Cruise
2 191 Cruise

Findings

Finding
12000 factor
12005 factor
12001 factor
24002 cause
24104 cause
24545 factor