N7497 Grumman G-164A accident

NTSB FTW83LA235 · 1983-05-13 · STUTTGART, AR

Docket — crew, injuries and powerplant

Factual narrative

AFTER LOADING THE ACFT WITH 50 GAL OF WATER, THE PLT TOOK OFF TO CONDUCT AERIAL APPLICAITON MANEUVERS & TO CALIBRATE THE ACFT'S SPRAY BOOM. AT THE END OF THE 1ST SWATH RUN ON A WESTERLY HEADING, HE PULLED UP OVER A POWER LINE, TURNED 90 DEG RIGHT, REVERSED THE TURN & WAS PASSING THRU A HEADING OF ABOUT 170 DEG WHEN THE ACFT STALLED. REPORTEDLY, THE PLT WAS TIGHTENING HIS TURN TO PRECLUDE OVERSHOOTING & WAS AT APRX 130 FT AGL WHEN THE STALL OCCURRED. THE ACFT IMPACTED ON ITS LEFT WING & CARTWHEELED TO A STOP. THE PLT REPORTED THE WIND WAS FROM 180 DEG AT 15 GUSTING 20 KTS.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
15
Wind direction
180
Wind speed (kt)
15
Temperature (F)
79
Distance from field
0.0

Aircraft

RegistrationMakeModelDamageFAR part
N7497 GRUMMAN G-164A SUBS 137

Sequence of events

#OccurrencePhase
1 250 Cruise
2 230 Cruise

Findings

Finding
20000 factor
19200 factor
24506 cause
24551