N4980G Cessna 172N accident

NTSB NYC83FA122 · 1983-05-20 · N. STONINGTON, CT

Docket — crew, injuries and powerplant

Factual narrative

THE ACFT COLLIDED WITH A TREE DURING A GO-AROUND AT NIGHT FOLLOWING A DOWNWIND PRECAUTIONARY LANDING. DURING THE FLT THE PLT HAD NOTED THE FUEL GAUGES AT LOW READINGS AND SAID HE SUSPECTED A 'FUEL LEAK'. HE MADE RADIO CALLS TO TRY TO GO TO AN ARPT BEFORE FUEL EXHAUSTION. SHORTLY AFTER RADIO CONTACT WAS MADE COMMUNICATIONS WERE LOST AND AN ELECTRICAL FAILURE WAS EXPERIENCED. THE PLT DESCENDED BELOW THE CLOUDS. HE ABANDONED ONE APPROACH BECAUSE THE FIELD LOOKED 'SHORT AND SOGGY.' THE NEXT APPROACH TO ANOTHER FIELD WAS MISSED HE SAID BECAUSE OF A TAILWIND. DURING GO-AROUND THE ENGINE QUIT AND THE ACFT COLLIDED WITH A TREE. EXAMINATION OF THE ACFT AFTER THE ACCIDENT SHOWED THE ALTERNATOR CIRCUIT BREAKERPOPPED. THE ALTERNATOR WAS REMOVED AND TESTED. IT PRODUCED A VOLTAGE INDICATION AT 700 RPMS TO 4500 RPMS. MAXIMUM VOLTAGE WAS 30 VOLTS. THE LOW VOLTAGE LIGHT BULB WAS INCORRECT AND THE WIRING WAS DISCONNECTED. THE WEATHER AT ACCIDENT TIME WAS CONDUCIVE TO CARBURETOR ICING.

Circumstances

Event type
Accident
Highest injury
Serious
Weather conditions
Instrument Meteorological Cond
Light condition
Day
Sky condition
OVC
Ceiling (ft)
500
Visibility (sm)
1
Wind direction
220
Wind speed (kt)
12
Distance from field
0.0

Aircraft

RegistrationMakeModelDamageFAR part
N4980G CESSNA 172N DEST 135

Sequence of events

#OccurrencePhase
1 130 Cruise
2 353 Cruise
3 220 Cruise

Findings

Finding
12011 factor
12017 factor
17202 factor
12001 factor
24102 cause
24542 cause
24030 cause
20000 factor
24546 factor
22304 cause
20200 factor
20000 factor
20000 factor
24026 cause