N35520 Cessna 172I accident

NTSB FTW83LA281 · 1983-06-16 · FORREST CITY, AR

Docket — crew, injuries and powerplant

Factual narrative

THE ACFT EXPERIENCED POWER FAILURE FROM ABOUT 20 FEET AGL DURING TAKEOFF FROM A PRIVATE GRASS STRIP. A WITNESS HEARD THEENGINE SPIT AND POP DURING THE TAKEOFF ROLL. HE SAID IT SOUNDED JUST LIKE HIS OLD PICKUP WHEN IT RUNS OUT OF GAS. AFTER THE ACCIDENT THE CARBURETOR BOWL WAS EXAMINED BY A MECHANIC WHO SAID IT CONTAINED A SMALL AMOUNT OF FUEL WITH NO TRASH OR WATER. THE LEFT FUEL TANK WAS 1/3 TO 1/2 FULL BUT THE RIGHT TANK HAD ONLY SEVEN QUARTS OF FUEL WITH ABOUT 6 DROPS OF WATER PRESENT. THE 7 QUARTS WERE COLLECTED BY REMOVING THE WING FROM THE ACFT BEFORE DRAINING IT. THE RESCUE PERSONNEL SAID THEY TURNED OFF THE FUEL BUT THE SELECTOR HAD BEEN ON THE RIGHT TANK WHEN THEY ARRIVED. THE OPERATORS FUEL MANAGEMENT PROCEDURE IS TO USE ONE HALF OF ONE TANK THEN SWITCH TANKS AND RUN THE OPPOSITE TANK DRY.

Circumstances

Event type
Accident
Highest injury
Minor
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
15
Wind direction
315
Wind speed (kt)
6
Temperature (F)
90
Distance from field
0.0
Airport elevation
250

Aircraft

RegistrationMakeModelDamageFAR part
N35520 CESSNA 172I DEST 091

Sequence of events

#OccurrencePhase
1 353 Cruise
2 180 Cruise
3 0 0

Findings

Finding
17001 factor
22201 cause
24030 cause
24032 cause
24505 cause