N4866 Grumman G-164A accident

NTSB FTW83LA351 · 1983-07-25 · CHILTON, TX

Docket — crew, injuries and powerplant

Factual narrative

DURING THE 1ST SWATH RUN THE PROP SEPARATED FROM THE ENG. A FORCED LANDING WAS MADE IN A PLOWED FIELD SHEARING ONE MAIN LANDING GEAR. THE ACFT THEN WENT THROUGH A BARBED WIRE FENCE. THE #4 CYLINDER WAS REMOVED TO INSPECT THE VIBRATION DAMPER PINS IN ACCORDANCE WITH AD 82-23-04. THE TRAILING PIN ON THE REAR VIBRATION DAMPER EVIDENCED CONSIDERABLE WEAR. THE WEAR HAD PROGRESSED TO THE POINT THAT THE DAMPER HAD BEEN DISPLACED FROM ITS NORMAL POSITION TO A POINT CAUSING INTERFERENCE WITH THE SKIRTS OF THE #2 & #3 PISTONS. THIS WEAR, IN ADDITION WITH MINOR WEAR TO THE LEADING PIN, CAUSED VIBRATION & SUBSEQUENT PROP SEPARATION. TWO DAYS AFTER THE ACCIDENT, AD 83-15-06 WAS ISSUED GROUNDING ALL ACFT WITH THE PROP-ENG COMBINATION THAT WAS INSTALLED ON THIS ACFT.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
10
Wind direction
180
Wind speed (kt)
3
Temperature (F)
81
Distance from field
0.0

Aircraft

RegistrationMakeModelDamageFAR part
N4866 GRUMMAN G-164A SUBS 137

Sequence of events

#OccurrencePhase
1 130 Cruise
2 180 Cruise
3 191 Cruise
4 310 Cruise

Findings

Finding
14004 cause
14004 cause
14502 cause
10401
20200 factor