NTSB DCA83AA037 · 1983-08-28 · HOT SPRINGS, AR · near HOT

Docket — crew, injuries and powerplant

Factual narrative

TURNING ONTO THE RWY THE COPLT OBSERVED A FLASH BEHIND HIS INST PANEL. HE THEN RECEIVED AN ELECT SHOCK TO HIS RIGHT ARM FROM THE RIGHT CONSOLE. A FIRE THEN ERUPTED AT THE LOWER RIGHT HAND CORNER OF HIS INST PANEL. THE CREW & PAX EVACUATED THE ACFT. THE INTERIOR OF THE ACFT WAS CONSUMED BY FIRE AS WELL AS MOST OF THE UPPER HALF OF THE FUSELAGE. EXAM OF THE RIGHT SIDE WIRE BUNDLE REVEALED NUMEROUS INDICATIONS OF ARCING BETWEEN WIRES & FROM WIRES TO GROUND. ONE WIRE WAS ARCED AT A POINT IN LINE WITH A PLASTIC OXYGEN LINE. THERE WAS ALSO AN OILY RESIDUE INSIDE THE WIRE BUNDLE. A SMALL SECTION OFTHE RIGHT BRAKE PRESSURE LINE EXHIBITED SIGNS OF ELECT ARCING. THE HYDRAULIC SYST PRESS GAGE COPPER LINE ALSO SHOWED SIGNS OF ARCING. THE PLASTIC OXYGEN LINES FROM THE THE COCKPIT SIDE OF THE FORWARD PRESSURE BULKHEAD TO THE COCKPIT OUTLETS HAD BEEN CONSUMED BY FIRE & THE OXYGEN SUPPLY WAS DEPLEATED.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Dusk
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
8
Wind direction
0
Temperature (F)
90
Nearest airport
MEMORIAL FIELD
Distance from field
0.0
Airport elevation
540

Aircraft

RegistrationMakeModelDamageFAR part
N503SS SWEARINGEN SA226TC SUBS 135

Sequence of events

#OccurrencePhase
1 171 Cruise

Findings

Finding
10012 cause
10012 cause
12013 cause
12013 cause
12013 cause
12501 cause
10012 cause
10000 cause