N597HJ Jordan ACEY DEUCY accident

NTSB CHI84LA036 · 1983-11-03 · CHESANING, MI · near 50G

Docket — crew, injuries and powerplant

Factual narrative

THIS WAS THE FIRST FLIGHT OF THE HOMEBUILT. SHORTLY AFTER TAKEOFF THE ENG QUIT DUE TO INADEQUATE GROUNDING. THE PLT RETURNED TO THE FIELD & MADE A SMOOTH LANDING. AT THE END OF THE ROLL OUT THE ANCHOR PLATE FOR THE LANDING GEAR TRUSS FAILED CAUSING THE LEFT GEAR TO COLLAPSE. THE PLT STATED THAT THE 3/4 INCH X 0.049, 4130 SQUARE TUBING USED FOR THE ANCHOR PLATE WAS TOO LIGHT TO CARRY THE ACFT LOADING & THAT IT MAY HAVE BEEN PREVIOUSLY CRACKED FROM HIGH SPEED TAXI TESTS.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
OVC
Ceiling (ft)
2000
Visibility (sm)
15
Wind direction
350
Wind speed (kt)
15
Temperature (F)
36
Nearest airport
CHESANING
Distance from field
0.0
Airport elevation
639

Aircraft

RegistrationMakeModelDamageFAR part
N597HJ JORDAN ACEY DEUCY SUBS 091

Sequence of events

#OccurrencePhase
1 351 Cruise
2 180 Cruise
3 191 Cruise

Findings

Finding
14800 cause
10404 cause
10404 cause
10404