N6739U Beech A36 accident
NTSB CHI84LA038 · 1983-11-05 · COLUMBUS, OH · near CMH
Docket — crew, injuries and powerplant
Factual narrative
ON THE RETURN FLT TO COLUMBUS, OH, THE ALTERNATOR WARNING LIGHT WAS ON. AFTER RECYCLING THE SWITCH, THE PLT SHUT DOWN ALL ELECTRICAL EQUIPMENT. DURING ARRIVAL AT THE DESTINATION, THE PLT PUT THE GEAR HANDLE DOWN, BUT NOTED A DIM UNSAFE GEAR LIGHT & A DISCHARGE INDICATION ON THE AMMETER. THE PLT STATED THAT SHE TRIED TO EXTEND THE GEAR MANUALLY. HOWEVER, DURING THE LANDING, THE NOSE & RIGHT MAIN GEAR COLLAPSED, THE ACFT SWERVED TO THE RIGHT & STRUCK A RWY LIGHT. THE ALTERNATOR & VOLTAGE REGISLATOR WEREREMOVED & TESTED, BUT BOTH OPERATED SATISFACTORILY. THEY WERE REINSTALLED ON THE ACFT & OPERATED AT DIFFERENT LOAD CONDITIONS, BUT STILL OPERATED NORMALLY. ALSO, THE EMERGENCY LANDING GEAR EXTENSION SYS WAS TESTED & WAS FOUND TO OPERATE NORMALLY.
Circumstances
- Event type
- Accident
- Highest injury
- None
- Weather conditions
- Visual Meteorological Cond
- Light condition
- Day
- Sky condition
- OVC
- Ceiling (ft)
- 3500
- Visibility (sm)
- 15
- Wind direction
- 320
- Wind speed (kt)
- 9
- Temperature (F)
- 39
- Nearest airport
- PORT COLUMBUS INT'L
- Distance from field
- 0.0
- Airport elevation
- 816
Aircraft
| Registration | Make | Model | Damage | FAR part |
|---|---|---|---|---|
| N6739U | Beech | A36 | SUBS | 091 |
Sequence of events
| # | Occurrence | Phase |
|---|---|---|
| 1 | 130 | Descent |
| 2 | 190 | Cruise |
| 3 | 310 | Cruise |
Findings
| Finding | |
|---|---|
| 12000 | cause |
| 12005 | |
| 12001 | |
| 10426 | |
| 24545 | |
| 20200 | factor |