N6787K Grumman G-164C accident

NTSB ATL82DA252 · 1982-08-27 · GUNNISON, MS

Docket — crew, injuries and powerplant

Factual narrative

THE PILOT REPORTED THAT HE SMELLED SOMETHING HOT WHILE SPRAYING. HE CHECKED THE INSTRUMENTS AND NOTED THAT THE OIL TEMPERATURE GAUGE WAS INDICATING OFF THE HIGH SIDE OF THE SCALE. HE STARTED TO MAKE A PRECAUTIONARY LANDING BUT THE ENGINE SEIZED DURING FINAL APPROACH. A FORCED LANDING WAS MADE IN A FRESHLY PLOWED FIELD WHERE THE PLANE NOSED OVER. A TEARDOWN OF THE ENGINE REVEALED THAT A MASTER ROD SPACER, PN 117547, HAD FAILED. WITHOUT THIS SPACER THE MASTER ROD WOULD NOT BE PROPERLY LUBRICATED, AND REPORTEDLY, THE ENGINE COULD SEIZE. FURTHER INVESTIGATION REVEALED THAT THE ENGINE HAD BEEN OVERHAULED 93 HRS PRIOR TO THE ACCIDENT. FOLLOWING THE OVERHAUL, THE ENGINE HAD A PROBLEM LEAKING OIL PAST THE VALVES, SO IT WAS TAKEN BACK TO THE OVERHAUL FACILITY. SEVEN CYLINDERS WERE REMOVED AND REWORKED. THE ACCIDENT OCCURRED FOLLOWING A BRIEF BREAK-IN PERIOD AFTER THAT.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
UNK
Ceiling (ft)
0
Visibility (sm)
5
Wind direction
0
Distance from field
0.0
Airport elevation
0

Aircraft

RegistrationMakeModelDamageFAR part
N6787K GRUMMAN G-164C SUBS 137

Sequence of events

#OccurrencePhase
1 351 Cruise
2 180 Cruise
3 300 Cruise

Findings

Finding
15208 cause
14001 cause
14005 cause
19200 factor