N23388 Cessna 172 accident

NTSB CHI83LA025 · 1982-10-25 · LANSING, IL · near 3HA

Docket — crew, injuries and powerplant

Factual narrative

THE ACFT HAD A COMPLETE ELECTRICAL FAILURE & THE PLT MADE AN EMERGENCY LANDING AT LANSING. THE PLT WAS UNABLE TO LOWER THE FLAP, & AFTER ENCOUNTERING GROUND FOG LANDED LONG, BOUNCED, & GROUND LOOPED TO AVOID RUNNING OFF THE END OF THE RWY.INVEST OF THE ELECT SYSTEM REVEALED THAT AN UNIDENTIFIABLE NOISE FILTER HAD BEEN INSTALLED IN THE LINE OF THE OUTPUT SIDE OF THE ALTERNATOR. TESTING REVEALED THAT THE NOISE FILTER DEVELOPED VOLTAGE SPIKES THAT COULD INCREASE LINE VOLTAGEMOMENTARILY TO 16 VOLTS. THE OVERVOLTAGE SENSOR WAS INOPERATIVE. THE SENSOR WAS PROBABLY TRIPPED BY EXCESSIVE SPIKING ON THE LINE VOLTAGE WHICH WOULD TURN OFF THE ALTERNATOR SYSTEM ILLUMINATING THE OVERVOLTAGE WARNING LIGHT. HOWEVER, THE BULB WAS FOUND BURNED OUT. THIS CONDITION CAN USUALLY BE CORRECTED BY RECYCLING THE MASTER SWITCH TO RESUME NORMAL ALTERNATING CHARGING.

Circumstances

Event type
Accident
Highest injury
Minor
Weather conditions
Instrument Meteorological Cond
Light condition
Night/Dark
Sky condition
UNK
Ceiling (ft)
0
Visibility (sm)
1
Wind direction
270
Wind speed (kt)
4
Nearest airport
LANSING
Distance from field
0.0
Airport elevation
0

Aircraft

RegistrationMakeModelDamageFAR part
N23388 CESSNA 172 SUBS 091

Sequence of events

#OccurrencePhase
1 130 Cruise
2 260 Cruise
3 300 Cruise

Findings

Finding
12000 cause
12011 cause
12000 cause
17208 factor
24113 cause
20100 factor
20000 factor
24546 factor
22111 factor
24537 cause