N2819Y Cessna 182E accident

NTSB LAX04CA147 · 2004-03-06 · Sonora, CA · near O22

Docket — crew, injuries and powerplant

Summary

The airplane collided with obstacles during an off airport landing in field, following a total loss of engine power. After takeoff, the pilot leveled off at 4,000 feet mean sea level (msl). The engine began running intermittently and then stopped. He glided away from populated areas below and landed in a field surrounded by hilly terrain. During the emergency landing rollout, the pilot was unable to stop the airplane, and collided with a barbed wire fence. The airplane continued down an embankment, resulting in the nose gear collapsing. The pilot thought the accident could have been prevented if he had accurately checked the fuel quantity prior to departure. The pilot reported no preimpact mechanical malfunctions or failures with the airplane.

Full narrative

On March 6, 2004, about 1220 Pacific standard time, a Cessna 182E, N2819Y, collided with obstacles during an off airport forced landing in field near Sonora, California, following a total loss of engine power. The pilot/owner operated the airplane under the provisions of 14 CFR Part 91. The commercial pilot and one passenger were not injured; the airplane sustained substantial damage. The flight departed Columbia Airport (O22), Columbia, California, about 1215, with a planned destination of Pine Mountain Lake Airport (Q68), Groveland, California. Day visual meteorological conditions prevailed for the local area flight, and no flight plan had been filed.

In a written statement, the pilot reported that after departure, he leveled off at 4,000 feet mean sea level (msl). While adjusting the mixture setting, the engine began to lose power. He placed the mixture back in the full-rich position, in an effort to regain power. The engine began running intermittently and then stopped. He glided away from populated areas below and landed in a field surrounded by hilly terrain. During the emergency landing rollout, the pilot was unable to stop the airplane, and collided with a barbed wire fence. The airplane continued down an embankment, resulting in the nose gear collapsing. During the accident the airplane incurred damage to the firewall, left wing, and horizontal stabilizer.

The pilot thought that the accident could have been prevented if he had accurately checked the fuel quantity prior to departure. The pilot reported no preimpact mechanical malfunctions or failures with the airplane.

Probable cause

the pilot's inadequate preflight inspection and failure to ensure adequate fuel was aboard, which resulted in fuel exhaustion and loss of engine power. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Ceiling (ft)
0
Wind direction
0
Nearest airport
Columbia Airport
Distance from field
5.0

Aircraft

RegistrationMakeModelDamageFAR part
N2819Y Cessna 182E SUBS 091

Sequence of events

#OccurrencePhase
1 350 Cruise
2 180 Cruise
3 310 Cruise

Findings

Finding
17001 cause
24002 cause
22204 cause
20200