N91734 Piper PA-46-350P accident

NTSB ATL04LA114 · 2004-03-02 · Montgomery, AL · near KMGM

Docket — crew, injuries and powerplant

Summary

The pilot landed on runway 28 with a crosswind from the left. After touchdown, the airplane yawed to the left. The pilot started correcting for the yaw but the correction felt to be too strong for the airplane to handle. The pilot allowed the airplane to drift to the left, eventually departing the runway on the left side onto the grass. Twenty yards from the runway, the nose gear dug into the soft grass and collapsed. Examination of the airplane revealed the nose gear collapsed, the propeller broken and damage to the firewall. The right main landing gear and the right wing tip were also bent. The nose gear trunnion was sent to the NTSB Materials Laboratory for a fracture analysis. The trunnion from the nose gear assembly was examined and the fracture faces contained no evidence of a fatigue crack or other preexisting condition leading to the fracture. According to the pilot's handbook the, the demonstrated crosswind component for the Piper PA-46-350P is 17 knots. The reported surface winds at the time of the accident were 200 degrees at 10 knots. The pilot's had accumulated a total of 1300 hours in the PA-46.

Full narrative

On March 2, 2004, at 1120 central daylight time, a Piper PA-46-350P, N91734, registered to and operated by a private pilot, nose gear collapsed during a landing on runway 28 at the Montgomery Regional Airport in Montgomery, Alabama. The personal flight operated under the provisions of Title 14 CFR Part 91 with no flight plan filed. Visual weather conditions prevailed at the time of the accident. The private pilot was not injured, and the airplane sustained substantial damage. The flight departed Montgomery Regional Airport at 1040.

The pilot landed on runway 28 with a crosswind from the left. After touchdown, the airplane yawed to the left. The pilot stated that he started correcting for the yaw but the correction felt to be too strong for the airplane to handle. The pilot allowed the airplane to drift to the left, eventually departing the runway on the left side onto the grass. Twenty yards from the runway, the nose gear dug into the soft grass and collapsed.

Examination of the airplane revealed the nose gear had collapsed, the propeller assembly was broken, and there was damage to the engine compartment firewall. The right main landing gear and the right wing tip were also bent. The nose gear trunnion was sent to the NTSB Materials Laboratory for a fracture analysis. The trunnion from the nose gear assembly was examined and the fracture faces contained no evidence of a fatigue crack or other preexisting condition leading to the fracture.

According to the pilot's handbook the, the demonstrated crosswind component for the Piper PA-46-350P is 17 knots. The reported surface winds at the time of the accident were 200 degrees at 10 knots. The pilot's had accumulated a total of 1300 hours in the PA-46.

Probable cause

The pilot's inadequate compensation for wind and his failure to maintain directional control during landing roll that resulted in the collapse of the nose gear. The crosswind was a contributing factor. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
Minor
Weather conditions
Visual Meteorological Cond
Sky condition
BKN
Ceiling (ft)
7500
Visibility (sm)
10
Wind direction
200
Wind speed (kt)
12
Temperature (F)
75
Nearest airport
Montgomery Regional
Distance from field
0.0
Airport elevation
0

Aircraft

RegistrationMakeModelDamageFAR part
N91734 Piper PA-46-350P SUBS 091

Sequence of events

#OccurrencePhase
1 260 Cruise
2 320 Cruise
3 192 Cruise

Findings

Finding
20000
24026 cause
24539 cause
19200
10405