N812CE Hughes 369D accident

NTSB LAX06LA288 · 2006-09-06 · Somis, CA

Docket — crew, injuries and powerplant

Summary

The utility company pilot and a power line inspector departed for an aerial observation patrol flight of company power lines. A ground-based witness, who was located north of the accident site, reported observing the helicopter fly into the power lines. The witness did not indicate that the helicopter took any evasive action prior to the collision. The helicopter came to rest about 200 feet north of the two severed power lines. The impacted power lines had been suspended from towers that were about 1,763 feet apart and had an east-to-west orientation. The helicopter's northerly impact course appeared nearly perpendicular to the orientation of the power lines, which were about 150 feet above ground level at the point of impact.

Full narrative

On September 6, 2006, at 1355 Pacific daylight time, a Hughes 369D, N812CE, collided with power lines while cruising about 3 miles north-northwest of Somis, California. The helicopter was owned and operated by the Southern California Edison Company (SCEC), Ontario, California, and it was substantially damaged upon impacting the ground. The commercial pilot and the power line inspector, both SCEC employees, were killed. The aerial observation flight was performed under the provisions of 14 Code of Federal Regulations Part 91. Visual meteorological conditions prevailed, and a company flight plan was filed. The flight originated from Camarillo, California, at 1321.

A ground-based witness, who was located north of the accident site, reported observing the helicopter fly into the power lines. The witness did not indicate that the helicopter took any evasive action prior to the collision.

According to the Federal Aviation Administration (FAA) coordinator who responded to the accident site, the helicopter came to rest about 200 feet north of the severed power lines. SCEC representatives, who were participating in the Safety Board's investigation, reported that the impacted Edison Company power lines had been suspended from towers that were about 1,763 feet apart and had an east-to-west orientation. The helicopter's impact course appeared nearly perpendicular to the orientation of the power lines. SCEC personnel also reported that the impacted lines were located about 150 feet above ground level.

SCEC personnel also reported that the accident occurred during a routine patrol flight. An examination of the Edison Company aluminum conductor steel reinforced wires was performed. Three of the wires exhibited impact damage, and two wires were severed.

SCEC personnel submitted a report of the accident to the Safety Board investigator. In pertinent part, they stated the following: "SCE is unaware of any exigent circumstances which may have affected [the pilot's] physical, mental or psychological health on the date of the accident."

An autopsy was performed by the County of Ventura Medical Examiner-Coroner, with specimens retained for toxicological analysis. No evidence of alcohol or screened drug substances was found during the toxicological tests.

Probable cause

The pilot's inadequate visual lookout, which resulted in a collision with wires. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
Fatal
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
10
Wind direction
250
Wind speed (kt)
9
Temperature (F)
79
Distance from field
0.0

Aircraft

RegistrationMakeModelDamageFAR part
N812CE Hughes 369D SUBS 091

Sequence of events

#OccurrencePhase
1 220 Cruise
2 230 Cruise

Findings

Finding
20200
24021 cause
19200