N5501A Bellanca 7GCAA accident

NTSB NYC06CA218 · 2006-09-04 · Farmingdale, NC · near BLM

Docket — crew, injuries and powerplant

Summary

During a banner pick-up, about 400 feet agl, the elevator cable separated. The airplane then pitched down and impacted a field. Examination of the airplane revealed rust and corrosion on an approximate 2-foot section of the failed elevator cable. The rust and corrosion were consistent with exposure to moisture over a period of time. Review of aircraft maintenance records revealed that the last annual inspection was completed about 10 months prior to the accident. The airplane had accumulated about 5,172 total hours of operation at the last annual inspection, and about 120 hours of operation since the inspection. The maintenance records noted that the cables were lubricated, but there was no record of rust or corrosion being detected.

Full narrative

The pilot was conducting banner-tow operations in a 1978 Bellanca 7GCAA. During a banner pick-up, about 400 feet agl, the pilot heard a "snap." At that time, both control sticks lost elevator control, and the airplane initially pitched nose up. The airplane then pitched about 20 degrees nose down. The pilot attempted to correct the descent with elevator trim and engine power, but the airplane impacted a field. Examination of the airplane by a Federal Aviation Administration (FAA) inspector revealed that the elevator cable had separated. Further examination revealed rust and corrosion on an approximate 2-foot section of the failed elevator cable. The rust and corrosion was consistent with exposure to moisture over a period of time. Review of aircraft maintenance records revealed that the last annual inspection was completed on November 13, 2005, about 10 months prior to the accident. The airplane had accumulated about 5,172 total hours of operation at the last annual inspection, and about 120 hours of operation since the inspection. The maintenance records noted that the cables were lubricated, but there was no record of rust and corrosion being detected.

Probable cause

An inadequate annual inspection of the airplane, which resulted in a total failure of the elevator cable during flight, and subsequent uncontrolled descent into terrain. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Accident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
10
Wind direction
300
Wind speed (kt)
10
Temperature (F)
72
Nearest airport
Monmouth Executive Airport
Distance from field
1.0

Aircraft

RegistrationMakeModelDamageFAR part
N5501A Bellanca 7GCAA SUBS 091

Sequence of events

#OccurrencePhase
1 130 Cruise
2 180 Cruise
3 230 Cruise

Findings

Finding
10732
24104 cause
19200