N295US Boeing 727-251 accident

NTSB CHI91IA078 · 1991-01-21 · ST. PAUL, MN · near MSP

Docket — crew, injuries and powerplant

Factual narrative

THE FLIGHT CREW WAS INFORMED BY THE TOWER OF A FIRE ON THE RIGHT SIDE OF THE AIRPLANE WHILE TAXIING FOR TAKEOFF. THE FIRE PRECEEDED BY UTILIZING THE AUXILARY POWER UNIT (APU) FOR A MAIN ENGINE START. THE MAIN ENGINE START WAS ABORTED WHEN THE APU FAILED TO DELIVER SUFFICIENT BLEED AIR PRESSURE. A POST INCIDENT INSPECTION OF THE APU DISCLOSED A LIBERATED TURBINE EXDUCER BLADE WHICH CAUSED AN IMBALANCE OF THE TURBINE WHEEL, ALLOWING SMOPKE AND FLAMES TO ESCAPE FROM THE APU EXHAUST ATOP THE RIGHT WING ROOT. THERE HAS BEEN 7 SERVICE DIFFICULTY REPORTS AND 4 ACCIDENTS/INCIDENTS ASSOCIATED WITH EXDUCER FAILURES IN THIS MODEL APU IN THE LAST FIVE YEARS.

Probable cause

THE PARTIAL FAILURE OF THE AIRPLANE'S AUXILIARY POWER UNIT, AND THE INADEQUATE COMPONENT PRODUCED BY THE MANUFACTURER. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Incident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Night/Bright
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
12
Wind direction
340
Wind speed (kt)
12
Temperature (F)
9
Nearest airport
MINEAPOLIS ST. PAUL
Distance from field
0.0
Airport elevation
841

Aircraft

RegistrationMakeModelDamageFAR part
N295US BOEING 727-251 MINR 121

Sequence of events

#OccurrencePhase
2 171 Cruise

Findings

Finding
13104