N849JS British Aerospace 3101 accident

NTSB BFO89IA047 · 1989-06-26 · BALTIMORE, MD · near BWI

Docket — crew, injuries and powerplant

Factual narrative

AFTER TOUCHDOWN, A PASSENGER INFORMED THE FLT CREW OF SMOKE AND SPARKS COMING FROM THE PANEL BEHIND THE CAPTAIN'S SEAT. THE ELECTRICAL SYSTEM AND ENGINE WERE SHUT DOWN AND PASSENGERS WERE DEPLANED AS A PRECAUTION. INSPECTION REVEALED A SHORT AT THE AIR CONDITIONING SYSTEM POWER CABLE/FUSE CONNECTION AT THE STATION 130 ELECTRICAL PANEL. THE PANEL WAS SCHEDULED TO BE INSPECTED EVERY 3600 HOURS. TOTAL ACFT TIME WAS 2117 HOURS. THE AIR CONDITIONING SYSTEM WAS A POST-PRODUCTION ADD-ON SYSTEM.

Probable cause

FAILURE OF MAINTENANCE PERSONNEL TO PROPERLY TORQUE THE POWER CONNECTION AT THE AIR CONDITIONING SYSTEM FUSE. The National Transportation Safety Board determined the probable cause of this accident.

Circumstances

Event type
Incident
Highest injury
None
Weather conditions
Visual Meteorological Cond
Light condition
Day
Sky condition
NONE
Ceiling (ft)
0
Visibility (sm)
5
Wind direction
150
Wind speed (kt)
6
Temperature (F)
88
Nearest airport
BALTIMORE/WASHINGTON
Distance from field
0.0
Airport elevation
146

Aircraft

RegistrationMakeModelDamageFAR part
N849JS BRITISH AEROSPACE 3101 MINR 135

Sequence of events

#OccurrencePhase
1 130 Cruise

Findings

Finding
12900
12013 cause
12016
24111 cause