N52311 Boeing 727-231 accident
NTSB NYC86IA093 · 1986-03-27 · BOSTON, MA · near BOS
Docket — crew, injuries and powerplant
Factual narrative
TWO OF 3 REQD FLT ATTENDANTS (F/A'S) WERE DISTRIBUTING PASSENGER (PAX) COATS AS THE ACFT WAS BEING TAXIED AFTER LNDG. SMOKE FM AN OVERHEATED AIR COND (A/C) PACK BGN ENTERING THE CABIN & THE F/A'S RETURNED TO THEIR DUTY STATIONS. THE FLT CREW STOPPED THE ACFT AT THE GATE & SHUT DWN THE ENGS, BUT LEFT THE APU RUNNING TO PROVIDE ELECTRICITY FOR LIGHTING. THEF/A'S OPENED THE L FWD DOOR & GND PSNL OPENED THE REAR STAIR DOOR TO DEPLANE THE PAX. THE CAPT MADE AN ANNOUNCEMENT TO KEEP THE PAX CALM, BUT SMOKE BCM DENSE & PAX OPENED THE EMERG EXITS OVR THE WINGS & BGN EXITING FM THEM. TWO PAX RCVD MINOR INJURIES WHILE EXITING OVR THE WINGS. AN INVESTIGATION REVEALED THE ACFT HAD BEEN DISPATCHED WITH THE R PACK COOL-ING FAN INOP AS AUTHORIZED BY THE MIN EQUIP LIST (MEL). DRG FLT, A RADIO INTERFERENCE FILTER IN THE A/C SYS FAILED WHICHALLOWED THE FWD PACK SHUT-OFF VALVE TO OPEN, BUT NOT CLOSE. THIS PERMITTED APU AIR TO RUN THE AFFECTED PACK EVEN THO THESWITCH WAS OFF & A CIRCUIT BRKR WAS PULLED. WITH THE ENGS SHUT DOWN & THE R COOLING FAN INOP, THE SYS OVERHEATED.
Circumstances
- Event type
- Incident
- Highest injury
- Minor
- Weather conditions
- Visual Meteorological Cond
- Light condition
- Night/Bright
- Sky condition
- NONE
- Ceiling (ft)
- 0
- Visibility (sm)
- 15
- Wind direction
- 220
- Wind speed (kt)
- 15
- Temperature (F)
- 54
- Nearest airport
- LOGAN INTL
- Distance from field
- 0.0
- Airport elevation
- 20
Aircraft
| Registration | Make | Model | Damage | FAR part |
|---|---|---|---|---|
| N52311 | BOEING | 727-231 | — | 121 |
Sequence of events
| # | Occurrence | Phase |
|---|---|---|
| 1 | 130 | Cruise |
Findings
| Finding | |
|---|---|
| 12906 | cause |
| 12900 | cause |
| 10003 |